In zbx_ipc_service_recv timeout:1.000
WebInstantly share code, notes, and snippets. negesti / gist:d6132dcd5fc78c629541010d4f06a496. Created March 12, 2024 12:03 Webservices: mysql-server: image: mysql:8.0 hostname: mysql-server container_name: mysql-server privileged: true expose: - 3306 command: --character-set-server=utf8 - …
In zbx_ipc_service_recv timeout:1.000
Did you know?
WebZBX_IPC_IPMI_SCRIPT_REQUEST は、通常監視に対する監視結果の処理となります。 ipmi_manager_process_value_result() が対応する関数となります。 717 static void … Web5 mei 2024 · In zbx_ipc_service_recv() timeout:1 End of zbx_ipc_service_recv():2 i also have : zbx_setproctitle() title:'proxy poller #1 [exchanged data with 0 proxies in 0.000512 …
WebZabbix_Server logs display : In zbx_ipc_service_recv () timeout:1. 27-04-2024, 10:31. Hello zabbix community. I am trying to setup zabbix in order to monitor our servers : rhel … Webr42690 r50411 1 1 /* 2 2 ** Zabbix: 3 ** Copyright (C) 2001-2024 Zabbix SIA: 3 ** Copyright (C) 2001-2024 Zabbix SIA: 4 4 ** 5 5 ** This program is free software; you ...
Web29 aug. 2024 · nobodysu commented on Sep 1, 2024. I will setup the environment and will try to fix this issue, within a week maybe. For now, please try to catch specific LLD reply … Web26 nov. 2024 · I increase DebugLevel to 4 on agent and there is bellow logs. 18587:20241225:152349.105 In zbx_tls_init_child() 18587:20241225:152349.108 …
Webipmi_manager.c (zabbix-6.2.7): ipmi_manager.c (zabbix-6.4.0rc1) skipping to change at line 20 skipping to change at line 20 ** This program is distributed in the hope that it will be useful,
diane blake and stephen smithWeb1. 问题现象. zabbix_server节点运行正常,zabbix_agent节点正常运行;. server节点和agent节点可以ping通,Telnet端口可用,TCP三次握手信息可以收到;. 2. 解决方案. 由于网络原因,导致TCP建立连接时间超时,TCP建立连接时间在agent配置文件可配置;. 修改配置:. Timeout=3 ... citb newportWeb**/ #ifndef ZABBIX_ZBXIPCSERVICE_H #define ZABBIX_ZBXIPCSERVICE_H #include "zbxalgo.h" #define ZBX_IPC_SOCKET_BUFFER_SIZE 4096 #define ZBX_IPC_RECV_IMMEDIATE 0 #define ZBX_IPC_RECV_WAIT 1 #define ZBX_IPC_RECV_TIMEOUT 2 #define ZBX_IPC_WAIT_FOREVER -1 typedef struct { /* … citbni grants onlineWeb1356675:20241020:104419.203 In zbx_ipc_service_recv () timeout:1.000 1356707:20241020:104419.203 zbx_setproctitle () title:'history syncer Home [processed … citb my learningWebA.FG...PS. [ZBXNEXT-6923,ZBXNEXT-6928] added High availability cluster support Merge in ZBX/zabbix from feature/ZBXNEXT-6923-5.5 to master * commit ... citb ni board membersWeb18 aug. 2024 · Remarks. The recv function is used to read incoming data on connection-oriented sockets, or connectionless sockets. When using a connection-oriented protocol, the sockets must be connected before calling recv. When using a connectionless protocol, the sockets must be bound before calling recv. The local address of the socket must be known. diane bollinger facebookWeb20 feb. 2024 · On tableau desktop in the server machine, under External Service Connection menù, the Rserve connection is succesful. Everywhere we have installed the same version of Tableau, 2024.3.2 (20243.18.1219.1533) 64-bit. After some investigation, i've discovered that when i pass some argument in the script with the ATTR() … citb north east